copper conductor xlpe insulated low voltage power cable
copper conductor xlpe insulated low voltage power cable
35KV and Below XLPE Cable IEC60502 ISO9001,GB/T 12706.2-12706
XLPE Insulated Cable is our main export item,Al or Cu conductor,armoured or non-armoured,which can be produced as per the requirements
XLPE Insulated Cable is used to transmit power on the power transmission and distribution line of A.C.50Hz, rated voltage 35kV or lower, and also used for Subway,Power station,Factory and Mine.It can be installed underground, in pipe, in trench or in tunnel.
XLPE Insulated Cable not only has excellent electric character, mechanical character, heat and aging-resistant character, environmental stress-resistant character and chemical corrosion- resistant character, but simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working as well.
We can also make fire resistant power cable
Product Description:
1. Conductors: copper or aluminum.
2. Both armored and non-armored type power cables are available.
3. Voltage rating: 6/10kV 8.7/15kV 26/35kV.
4. PVC or PE sheathed.
5. Standards: IEC 60502. IEC, BS, DIN, ASTM, CSA, NFC, AS, GOST etc. Or other special characteristics as customers request.
Rated Voltage,Core Numbers & Nominal Cross-section Area as following Table
| 1st class | 0.6/1 | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 18/30 | 21/35 | |||
2nd class | 1/1 | 3/3 | 6/6 | 8.7/10 | 12/15 | 18/20 | - | 26/35 | ||||
1 Core | Section area(mm2) | 1.5-800 | 25-800 | 25-800 | 25-800 | 35-800 | 50-800 | 50-800 | 50-800 | |||
2 Core | Section Area(mm2) | 1.5-185 | / | / | / | / | / | / | / | |||
3 Core | Section area(mm2) | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | |||
4 Core | Section Area(mm2) | 2.5-400 | 25-400 | / | / | / | / | / | / | |||
5 Core | Section area(mm2) | 2.5-400 | 25-400 | / | / | / | / | / | / |
Cable Types, Names and Application
Type | Description | Application | |
Cu Core | Al Core | ||
YJV ZR-YJV | YJLV ZR-YJLV | Cu(Al)Core, XLPE Insulated, PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, PVC Sheathed flame- retardant Power Cable | Can be laid in indoor, outdoor, tunnels, cable channels, reinforced concrete pipelines and loose soil. Cable should not bear outer mechanic force, but can bear a certain tractional force. |
YJV22 ZR-YJV22 | YJLV22 ZR-YJLV22 | Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed flame- retardant Power Cable | Laid underground. Cable can bear outer mechanic force, but should not bear large tractional force. |
YJV32 ZR-YJV32 | YJLV32 ZR-YJLV32 | Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable | Laid in indoor, tunnels and mines. Cable can bear outer mechanic force and fairly large tractional force. |
YJV42 ZR-YJV42 | YJLV42 ZR-YJLV42 | Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed flame- retardant Power Cable | Can be laid in vertical section, indoor, tunnels and mines. Cable can bear outer mechanic force and very large tractional force. |
Application conditions
1. The long-time permissible operation temperature of conductor shall not be higher than 90oC.
2. Conductor maximum short circuit (not more than 5 seconds) temperature shall not be higher than 250 oC.
3. The power cable is not limited by drop in level when being laid, and the ambient temperature shall not be lower than 0 oC.
If so, the cable should to be preheated.
4. Perfect chemical stability, resistant against acids, alkalis, grease and organic solvents, and flame.
copper conductor xlpe insulated low voltage power cable